<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-04 20-24-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 4/5, 57 dBuV RTL
Pilot RDS Phase Difference
7.3 kHz 4.3 kHz -4 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 74 kHz 9151 3,3767
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,5 dBr 6,04 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 1 2 20:24, 4.01.2025
RT
"RTL - ON REFAIT LE MATCH "
AF EON
92.1, 93.1, 93.2, 94.3, 95.3, 95.4, 97.1, 98.4, 98.5, 98.9, 99.8, 100.8, 101.2, 102.0, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 104.4, 104.5, 105.0, 106.0 MHz -
FM Scope Station: 104.30 MHz, signal: 4/5 (55 dBuV) Max at: 74 kHz MIN: 13 kHz % above 75 kHz: 3,3767 Acquired: 2025/01/04 20:23:07 Total samples: 9151 Equivalent time: 0:07:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 5,5 dBr AVE: 6,04 dBr % above 10,0 dBr: 0,0 Last value: 6,4 dBr (2025/01/04 20:23:07) Station: 104.30 MHz, signal: 4/5 (54 dBuV) 20:16 20:17 20:18 20:19 20:20 20:21 20:22 20:23 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality